If you’re searching for a furnace to complete your HVAC system, Carrier’s offerings should be a great fit. Here’s what to expect from Carrier furnace costs. Expert Advice On Improv... Carrier Enterprise Mid-Atlantic Technical Support Site Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39...

We have 2 Carrier 48FC Series manuals available for free PDF download: Controls, Start-Up, Operation And Troubleshooting, Installation Instructions. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting …

NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Two-stage cooling capacity control on all models. SEER to 16.0. Gas efficiencies up to 82%. Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C)

14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyCarrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ...Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas HeatSame footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time; Field convertible from vertical to horizontal airflow for slab mounting (sizes 04-16) Provisions for thru-the-bottom power entry capability as standard; Dedicated vertical and horizontal airflow models available (sizes 17 to 30 only)

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ...

SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.

View and Download Carrier WeatherMaker 48FC04-07 installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puron R-410A Refrigerant. ... The W7220 controller does not actually control the fan On single phase 48FC 3 to 5 ton units, if reduced the heat- speed or the heat output of the unit, and only ...3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The …CarrierCarrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI;Catalog No. 04-53480332-01 Printed in U.S.A. View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download.

48FC 08-14 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air ...04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerCarrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI;NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)CE - carrierenterprise.comWith Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ...Hey Everyone, Working on a Carrier RTU unit model# 48TCEA06A2A5A0A0A0. Customer complaint "thermostat has no power." Found 5 amp breaker tripped on transformer. Whenever R and Y1 closes it pulls 10 amps and trips 5 amp breaker. I removed wires from both contactor solenoids (24v circuit) and still trips. I …

Performance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single …Carrier

Carrier 48TCED Manuals | ManualsLib. Check Details. Carrier 58UHV Product data | Manualzz. Check Details. carrier chiller data. Check Details. WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check …All 10 ton units and 6 to 8.5 ton high efficiency units offer variable speed direct drive motors. Direct Drive Plenum Fan The following units are equipped with a direct drive plenum fan design (all 10 ton units, 6 (074) to 8.5 ton high efficiency units, and optional on 7.5 (092) to 8.5 ton standard efficiency units). Plenum fan designCarrierChoosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi...Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages)Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...The Performance heat pump, with two-stage compressor, lets you enjoy smooth, consistent comfort, quieter operation and improved air flow all year long. It's an extra-efficient heat pump system that also utilizes a multi-speed blower to help achieve enhanced summer dehumidification. Includes tin-plated copper coils for enhanced corrosion resistance.Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated withCarrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

PALM BEACH GARDENS, Fla., March 6, 2023 /PRNewswire/ -- Carrier Global Corporation (NYSE: CARR), the leading global provider of healthy, safe, sus... PALM BEACH GARDENS, Fla., Marc...

View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A …

15 Oct 2023. 48fc packaged hvac ecoblue rooftop rtu finalists weathermaker weathermaster specifying named variable speed Carrier 14 seer air conditioner Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology ... Carrier 58uhv product data Manualslib manuals 48tc Packaged rooftop units ecoblue single carrier 48fc ...View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,...Most of Carrier’s 3−12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. ... SEER up to 15.6, EER up to 13.0 IEER’s up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV (Staged Air Volume) 2−speed/VFD48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files.Carrier 48GC Series Pdf User Manuals. View online or download Carrier 48GC Series Installation Instructions ... Gas Heat (48FC and 48GC) 8. Controls Quick Set- -Up. 8. Control Set Point and Confirmation Log. 8. Initial Startup. 8. ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector ...Carrier48VG. Gas heating and electric cooling with up to 16 SEER2 for enhanced energy savings with enhanced comfort features. Ultra-low NOx models available for California. 4.7 out of 5 stars. 45 Reviews. 5 Star. 80%. 4 Star. 13%.48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged …

7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlySEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Exclusive IGC solid-state control for on-board diagnostics ...Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas HeatInstagram:https://instagram. kogo radio san diegotroy bilt xp 3000 psi pressure washer parts diagramloon range mappublix buffalo road pharmacy Trane Heating & Air ConditioningCarrier Enterprise Mid-Atlantic Technical Support Site odyssey sliding door won't openwebbie wife laura Leading Efficiencies. The Carrier WeatherExpert® Packaged Rooftop Unit series provides comfort and energy efficiency never seen before. WeatherExpert units, available in 3-23 ton sizes, use multi-stage compressors, a single refrigerant circuit and SAV™ (Staged Air Volume) logic to provide part-load efficiencies that lead the industry. jag one south ave These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1 IEER …12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...